What are the monitor parameters?

Six general parameters:

Heart rate: refers to the times of heart beat per minute;

Blood pressure: Including invasive and non-invasive. Invasive refers to the arterial blood pressure displayed by the monitor when the sensor is implanted in the artery; non-invasive refers to the blood pressure measured by the cuff;

Respiratory rate: refers to the times of respiration per minute;

Oxygen saturation: oxygen content in fingertip blood;

ECG: Observe whether the patient has arrhythmia;

Temperature: patient 's real-time temperature.

JCR Medical are manufacturer and our company main monitor consumables, provides disposable pressure transducers qualified CE and ISO13485, SPO2 sensor probes, temperature sensor probes, ECG, Adult/child ECG clips, ECG Suction Electrode, NIBP and so on, ODM&OEM are both welcomed.

What Are Six General Parameters Of Monitor0ho

The six general parameters of multi-parameter monitor are also the six vital sign parameters used to monitor the human body. On the surface, these signs seem not to be special, such as the real-time body temperature of the patient. This feature seems to be even easily overlooked in peacetime. However, in fact, for the patient, some subtle changes in the body temperature even play a crucial role in the patient 's life.

Six general parameters, also known as six vital parameters, affect the life and health of patients.

The multi-parameter monitor was used as ECG – electrocardiogram NIBP – blood pressure PLETH – heart rate SPO2 – oxygen saturation RESP – respiration.

Prepare items: mainly include ECG monitor, ECG blood pressure plug-in connecting wire, electrode piece, normal saline cotton ball and matching blood pressure cuff.

Operating steps:

1. Connect the ECG monitor power supply.

2. the patient was placed in the supine or semi-recumbent position.

3. turn on the main switch.

4. the skin at the electrode attached to the patient 's chest was wiped with a saline cotton ball.

5. Apply the electrode piece, connect the ECG lead wire, and the ECG oscillogram appears on the screen

6. the cuff was tied to two transverse fingers on the antecubital fossa. Press Measure - Set Alarm Limit - Measure Time.

In general, there will be operation training before the operation according to the instrument. The simple step is to connect the accessories (generally ECG, blood oxygen and blood pressure) to the interface panel of the instrument first, connect the other end to the patient, connect the ECG with a three-lead, clamp the patient's finger with the oximeter probe, sleeve the cuff on the arm, start the instrument, the ECG oximeter figure data will be available, press the blood pressure key, and the instrument automatically measures the blood pressure.