Nihon Kohden compatible disposable SPO2 probes

The patient sensor end of the product is clamped the patient’s index finger with (Thumb, middle finger or others, great toes), and the device connector is connected to compatible monitors or oximeters with SPO2 extension cord. The product adopts 660nm red light and 905nm Infrared light as incident light source, tests light intensity through tissue to obtain SPO2 value as well as pulse rate

    PRODUCT INTRODUCTION

    Basic performance of product:

    ● Lighting tube 660 nm/905 nm/940 nm, maximum output power: 2 mw; 

    ● SPO2 test range: 70% ~ 100%; accuracy: ± 3% when 70% ~ 89%, ± 2% when 90% ~ 100%; 

    ● Pulse rate test range: 30 ~ 245 bpm; accuracy: ± 3 bpm when 30 bpm-245 bpm; 

    ● The maximum allowable temperature of the probe in contact with human body does not exceed 41℃.

    Nihon Kohden compatible disposable SPO2 probes (1)mpz
    Nihon Kohden compatible disposable SPO2 probes (2)8we
    Nihon Kohden compatible disposable SPO2 probes (4)4fy

    Application method

    Remove the dust liner from the probe end and find the transparent window, below the window. The best position for optics to use this product is the index finger. The sensor can also be used on the little or middle finger and other fingers or big toe if there is an inconvenience. 

    Caution: When selecting a transducer site, it is preferable to select an extremity that does not have an arterial line, blood pressure cuff, or transfusion cannula. 

    Adjust the direction of this product so that the dashed line in the sensor is in the center of the fingertip Wrap the tape without the end of the cable around the fingertip. Note: Be sure to secure the cable to the back of your hand. 

    Fold the cable end towards the finger so that the plastic window is directly opposite, and then firmly wrap the tape around both sides of the finger. 

    Plug this product into the saturation tester and confirm whether it is operated correctly as described in the tester operation manual. 

    Note: If the sensor cannot stably track the pulse condition, it may be because it is improperly placed, or the sensor is placed too thick, too thin, or has significant pigmentation, or the color is too light due to other reasons (e.g., due to the use of externally colored products such as nail polish, stains, or tinted foundation), so that normal light cannot be transmitted. In any of these cases, reposition the sensor or use a different type of sensor on a different site. 